Purchase Your Fire Extinguisher Servicing Online Now - Available Across The Country
1 items added to basket
Tube Based Suppression System (CO2) - Indirect System
INC VAT
Code:
Safeguarding high-risk micro-environments from fire can be a significant challenge for your premises. This tube based suppression system is designed to provide the fire protection you need in those challenging spaces.
The Tube Based Suppression System (CO2) - Indirect System, is designed to swiftly tackle fires in high-risk enclosed spaces. For example, cabinets, servers, engines and wind turbines.
This is an indirect system, meaning that the extinguishing agent is discharged from a metal conduit across multiple high risk points. The agent is discharged after the heat sensitive tube breaks, which causes the pressure to drop and the metal conduit to tackle the fire.
This fire suppression system uses CO2. CO2 leaves no residue behind, meaning no clean up is necessary which makes it ideal for use on sensitive electronic equipment.
Classification: Works on class B, C, and electrically started fires.
Self- Actuated: Does not require any power supply and will function normally in the event of a power outage.
Electronics-Friendly: The system is safe to be used on electronics as CO2 as an agent is kinder on electronics than the majority of extinguishing agents available in the market.
High-value Risk Protection: Suitable for protection on a range of high-value risks as it virtually eliminates damage to high-tech equipment, artwork and other delicate and sensitive objects.
No Clean-up Required After Discharge: After a discharge, the extinguishing agent can be removed by simple ventilation.
24-hour Protection: Automatic detection and actuation controls ensure fire protection is always ‘on’.
Flexible Design: Flexible tubing allows protection in areas that are difficult to access and may not be able to accommodate any other means of defection.
International Quality Standards: Manufactured to the highest global and national standards like BSI, ISI and CE and is also certified for Forced and Natural Air Flow cabinet applications.
Rugged Design: Can withstand even harsh conditions where other types of detection systems might be rendered inadequate.
Residue-Free: CO2 won’t leave behind oily residue, particulate or corrosive material.
Product Code | Unit of Measure | CF-000246 | CF-001289 | CF-001317 |
Description | 2Kg, CO2 IHP system | 5Kg, CO2 IHP system | 20Kg, CO2 IHP system | |
Capacity of Agent | KG | 2 | 5 | 20 |
Certification | PED UKCA-PED BSI TESTED | PED UKCA-PED BSI TESTED | PED UKCA-PED BSI TESTED | |
Diameter of Shell | MM | 108 | 140 | 232 |
Total Height (approx.) | MM | 590 | 770 | 1150 |
MOC of Shell | Carbon Steel (37Mn/ 34CrMo4) | Carbon Steel (37Mn/ 34CrMo4) | Carbon Steel (37Mn/ 34CrMo4) | |
Mini. Wall Thickness | MM | 2.0 | 2.5 | 3.5 |
Test Pressure | BAR | 250 | 250 | 250 |
Anti-Corrosive Treatment | Outer surfaces are EP Powder coated having Thickness 50 Micron Min. RAL Shade 3000 | Outer surfaces are EP Powder coated having Thickness 50 Micron Min. RAL Shade 3000 | Outer surfaces are EP Powder coated having Thickness 50 Micron Min. RAL Shade 3000 | |
Service Pressure | BAR | 17-23 | 17-23 | 17-23 |
Type of Operating Mechanism | Automatic / Manual | Automatic / Manual | Automatic / Manual | |
Type of Pressure Gauge | Magnetic Bourdon Tube Type | Magnetic Bourdon Tube Type | Magnetic Bourdon Tube Type | |
Type of Dis. pipe & Length | MM | Delivery pipe OD 10MM x 1MM Wall Thk. 4 M Besides Nozzle Network | Delivery pipe OD 10MM x 1MM Wall Thk. 6 M Besides Nozzle Network | Delivery pipe OD 10MM x 1MM Wall Thk. 20 M Besides Nozzle Network |
No of Max. nozzles | 4 | 6 | 20 | |
Type of valve | Direct High-Pressure Valve (IHP) with single outlet | Direct High-Pressure Valve (IHP) with single outlet | Direct High-Pressure Valve (IHP) with single outlet | |
Operating Temperature Range | °C | -20 C to 60 C | -20 C to 60 C | -20 C to 60 C |
Applicable to Type of Fire | B, C ,& Electrical Started Fire | B, C ,& Electrical Started Fire | B, C ,& Electrical Started Fire | |
Product Warranty | YEAR | 1 | 1 | 1 |
Safeguarding high-risk micro-environments from fire can be a significant challenge for your premises. This tube based suppression system is designed to provide the fire protection you need in those challenging spaces.
The Tube Based Suppression System (CO2) - Indirect System, is designed to swiftly tackle fires in high-risk enclosed spaces. For example, cabinets, servers, engines and wind turbines.
This is an indirect system, meaning that the extinguishing agent is discharged from a metal conduit across multiple high risk points. The agent is discharged after the heat sensitive tube breaks, which causes the pressure to drop and the metal conduit to tackle the fire.
This fire suppression system uses CO2. CO2 leaves no residue behind, meaning no clean up is necessary which makes it ideal for use on sensitive electronic equipment.
Classification: Works on class B, C, and electrically started fires.
Self- Actuated: Does not require any power supply and will function normally in the event of a power outage.
Electronics-Friendly: The system is safe to be used on electronics as CO2 as an agent is kinder on electronics than the majority of extinguishing agents available in the market.
High-value Risk Protection: Suitable for protection on a range of high-value risks as it virtually eliminates damage to high-tech equipment, artwork and other delicate and sensitive objects.
No Clean-up Required After Discharge: After a discharge, the extinguishing agent can be removed by simple ventilation.
24-hour Protection: Automatic detection and actuation controls ensure fire protection is always ‘on’.
Flexible Design: Flexible tubing allows protection in areas that are difficult to access and may not be able to accommodate any other means of defection.
International Quality Standards: Manufactured to the highest global and national standards like BSI, ISI and CE and is also certified for Forced and Natural Air Flow cabinet applications.
Rugged Design: Can withstand even harsh conditions where other types of detection systems might be rendered inadequate.
Residue-Free: CO2 won’t leave behind oily residue, particulate or corrosive material.
Product Code | Unit of Measure | CF-000246 | CF-001289 | CF-001317 |
Description | 2Kg, CO2 IHP system | 5Kg, CO2 IHP system | 20Kg, CO2 IHP system | |
Capacity of Agent | KG | 2 | 5 | 20 |
Certification | PED UKCA-PED BSI TESTED | PED UKCA-PED BSI TESTED | PED UKCA-PED BSI TESTED | |
Diameter of Shell | MM | 108 | 140 | 232 |
Total Height (approx.) | MM | 590 | 770 | 1150 |
MOC of Shell | Carbon Steel (37Mn/ 34CrMo4) | Carbon Steel (37Mn/ 34CrMo4) | Carbon Steel (37Mn/ 34CrMo4) | |
Mini. Wall Thickness | MM | 2.0 | 2.5 | 3.5 |
Test Pressure | BAR | 250 | 250 | 250 |
Anti-Corrosive Treatment | Outer surfaces are EP Powder coated having Thickness 50 Micron Min. RAL Shade 3000 | Outer surfaces are EP Powder coated having Thickness 50 Micron Min. RAL Shade 3000 | Outer surfaces are EP Powder coated having Thickness 50 Micron Min. RAL Shade 3000 | |
Service Pressure | BAR | 17-23 | 17-23 | 17-23 |
Type of Operating Mechanism | Automatic / Manual | Automatic / Manual | Automatic / Manual | |
Type of Pressure Gauge | Magnetic Bourdon Tube Type | Magnetic Bourdon Tube Type | Magnetic Bourdon Tube Type | |
Type of Dis. pipe & Length | MM | Delivery pipe OD 10MM x 1MM Wall Thk. 4 M Besides Nozzle Network | Delivery pipe OD 10MM x 1MM Wall Thk. 6 M Besides Nozzle Network | Delivery pipe OD 10MM x 1MM Wall Thk. 20 M Besides Nozzle Network |
No of Max. nozzles | 4 | 6 | 20 | |
Type of valve | Direct High-Pressure Valve (IHP) with single outlet | Direct High-Pressure Valve (IHP) with single outlet | Direct High-Pressure Valve (IHP) with single outlet | |
Operating Temperature Range | °C | -20 C to 60 C | -20 C to 60 C | -20 C to 60 C |
Applicable to Type of Fire | B, C ,& Electrical Started Fire | B, C ,& Electrical Started Fire | B, C ,& Electrical Started Fire | |
Product Warranty | YEAR | 1 | 1 | 1 |
SK001/022
ex vat
FAC001/056
ex vat
8812
ex vat
FAEKIT2
ex vat
SB001/004
ex vat
Fire Protection Shop specialise in the supply of high-quality fire extinguishers. There are many different classifications of fire and so our products include a variety of different extinguisher types. For example, we offer water or foam fire extinguishers for solid combustibles and carbon dioxide fire extinguishers for flammable liquid or electrical fires. Each extinguishing agent comes with its benefits. Typically, water extinguishers are cheaper, produce a cooling effect and prevent reignition once the fire has been extinguished. Carbon dioxide extinguishers are clean agents, they leave no residue, are suitable for electrical fires and are often used on liquid fires which include petrol, oil or other solvents.
In addition to our extinguishers, we offer a range of fire safety products to both domestic and commercial premises. This includes the supply of fire blankets, extinguisher stands, smoke alarms, first aid kits and much more. Our entire range is sourced from reputable brand manufacturers at competitive prices. Also, all of our products carry a full warranty and guarantee and are supplied with relevant fixings where applicable.
So, for fire extinguishers, alarms and all your other fire safety needs, trust Fire Protection Shop to give you the quality, expertise and service you require.
We use cookies to enhance your site experience. Choose your preferences below.