We Recommend
Bestseller
from
INC VAT
Code: SAV001/006
The Haes Excel-EN conventional fire alarm panel is a networkable fire alarm control panel with selectable SAV wire or conventional 4 wire configeration. Simple to install and operate the Haes Excel can support two stage activation before sounding the alarm.
LPCB certified to the latest revisions of EN54 parts 2 and 4, offers an array of user and installer-friendly features at a very competitive price.
Lockable mild steel powder coated cabinet measures 450mm x 300mm x 85mm and has space for 2 x 7.0Ah batteries.
A wide range of engineering functions are also provided including selectable zone delays, coincidence and non-latching zone options. Comprehensive test and fault finding facilities are also provided.
2 monitored detection zones
2 monitored sounder outputs
Fire and Fault Relays, 3A 30v rated
Class change input
Alert input
Fire & fault switched -ve outputs
False alarm mode
Test mode, with or without sounders
Disable zones, sounder O/Ps & Aux O/Ps
Alarm load, 800mA shared between all sounder outputs
Fused sounder circuits @ 500mA with resettable fuses.
Twin Wire, selection by DIL switch
Activate controls via keyswitch or code entry
Soft tactile buttons for controls & programing
Conventionally wired, compatible with most detectors
Integral detector removal monitoring
3 Amp switch mode power supply Nom 27V DC
Requires 2 x 7Ah 12V batteries
2 monitored sounder outputs
2 Aux C/O relays (1 x Fire) (1 x Fault). voltage free
Class change I/P
Alert I/P
Fire & fault switched -ve outputs
Additional sounder circuits, relays & switched -ve outputs available via high spec expansion zone cards
Program delays to ouputs
Dependency modes A, B & C
Test mode, with or without sounders
Disable zones, sounder O/Ps, aux O/Ps & delays
Alarm load, 2.4A shared between all sounder outputs
All sounder circuits are fused @ 500mA with resettable fuses
Metal casing | 1.2mm mild steel |
Battery capacity | 2 x 7Ah 12V batteries |
Height | 250mm |
Width | 300mm |
Depth | 80mm |
The Haes Excel-EN conventional fire alarm panel is a networkable fire alarm control panel with selectable SAV wire or conventional 4 wire configeration. Simple to install and operate the Haes Excel can support two stage activation before sounding the alarm.
LPCB certified to the latest revisions of EN54 parts 2 and 4, offers an array of user and installer-friendly features at a very competitive price.
Lockable mild steel powder coated cabinet measures 450mm x 300mm x 85mm and has space for 2 x 7.0Ah batteries.
A wide range of engineering functions are also provided including selectable zone delays, coincidence and non-latching zone options. Comprehensive test and fault finding facilities are also provided.
2 monitored detection zones
2 monitored sounder outputs
Fire and Fault Relays, 3A 30v rated
Class change input
Alert input
Fire & fault switched -ve outputs
False alarm mode
Test mode, with or without sounders
Disable zones, sounder O/Ps & Aux O/Ps
Alarm load, 800mA shared between all sounder outputs
Fused sounder circuits @ 500mA with resettable fuses.
Twin Wire, selection by DIL switch
Activate controls via keyswitch or code entry
Soft tactile buttons for controls & programing
Conventionally wired, compatible with most detectors
Integral detector removal monitoring
3 Amp switch mode power supply Nom 27V DC
Requires 2 x 7Ah 12V batteries
2 monitored sounder outputs
2 Aux C/O relays (1 x Fire) (1 x Fault). voltage free
Class change I/P
Alert I/P
Fire & fault switched -ve outputs
Additional sounder circuits, relays & switched -ve outputs available via high spec expansion zone cards
Program delays to ouputs
Dependency modes A, B & C
Test mode, with or without sounders
Disable zones, sounder O/Ps, aux O/Ps & delays
Alarm load, 2.4A shared between all sounder outputs
All sounder circuits are fused @ 500mA with resettable fuses
Metal casing | 1.2mm mild steel |
Battery capacity | 2 x 7Ah 12V batteries |
Height | 250mm |
Width | 300mm |
Depth | 80mm |
SK001/022
ex vat
FAC001/056
ex vat
8812
ex vat
FAEKIT2
ex vat
SB001/004
ex vat
Fire Protection Shop specialise in the supply of high-quality fire extinguishers. There are many different classifications of fire and so our products include a variety of different extinguisher types. For example, we offer water or foam fire extinguishers for solid combustibles and carbon dioxide fire extinguishers for flammable liquid or electrical fires. Each extinguishing agent comes with its benefits. Typically, water extinguishers are cheaper, produce a cooling effect and prevent reignition once the fire has been extinguished. Carbon dioxide extinguishers are clean agents, they leave no residue, are suitable for electrical fires and are often used on liquid fires which include petrol, oil or other solvents.
In addition to our extinguishers, we offer a range of fire safety products to both domestic and commercial premises. This includes the supply of fire blankets, extinguisher stands, smoke alarms, first aid kits and much more. Our entire range is sourced from reputable brand manufacturers at competitive prices. Also, all of our products carry a full warranty and guarantee and are supplied with relevant fixings where applicable.
So, for fire extinguishers, alarms and all your other fire safety needs, trust Fire Protection Shop to give you the quality, expertise and service you require.
We use cookies to enhance your site experience. Choose your preferences below.